Type:CX-LCM-1607A lab conductivity meter

Illustrate:It can be widely used for continuous monitoring of conductivity values of the solutions in thermal power plants, chemical fertilizer, metallurgy, environmental protection, pharmaceutical industry, biochemical industry, foodstuff and running water.

CX-LCM-1607A Lab Conductivity Meter

Main Features
1.Double-row nixie tube: To show the conductivity and temperature values respectively
2.Computer-based: It adopts the high-performance CPU chip, high-precision AD conversion technology and SMT technology to complete the multi-parameter measurement, temperature compensation and automatic range switching, with high precision and good repeatability.
3.Reliability: Single board structure, touch button, no switch knob or potentiometer
4.Automatic conversion of measuring frequency: To avoid the electrode polarization and improve the Measurement accuracy
5.25°C Conversion: Temperature compensation automatic measurement/manual input, with the waterproof and anti-corrosion design
6.Network function: RS232 bi-directional communication; it can be equipped with a printer or TLab8.0communications and data processing software
7.Measurable high-purity water: Equipped with titanium alloy electrode with the constant of 0.01 cm-1 and an airtight measuring cell; automatic prompting for measuring terminal.
 
Main parameters

Display Double-row Nixie tube displays the conductivity
and temperature values respectively
Measuring range  (1-30000) μ s/cm, 0-99.9 °C
Electrode constant 0.01-30 μ s/cm (Electrode: K=0.01) ,0.1~300 μ s/cm
(Electrode: K=0. 1)
1.0~3000 μ s/cm (Electrode: K=1.0),10~30000 μ s/cm
(Electrode: K=10.0)
Resolution 0.001μ s/cm, 0.1°C
Electrode constant 0.001~15.0 cm-1 set by the software
Temperature compensated range automatic: 0-99.9 °C, manual: 0-99.9 °C
Temperature coefficient 0~10%/°C (with 25°C as the reference temperature)
Accuracy ±l0%FS, ±0 3°C
Communication interface RS232 bi-directional communication interface
Power supply AC220V ± 22V, 50Hz ± 1Hz, external power supply
Working conditions ambient temperature: 0-60°C; relative humidity: ≤90
Power-down memory: > 5 years
Note:Standard configuration: One secondary instrument; one power supply; one bright or platinum black conductivity electrode with constant l.0; one temperature electrode; a set of electrode support

Last:CX-LCM-1601 lab conductivity me.. Next:CX-LCM-1607 laboratory conducti..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關(guān)閉
欧美午夜精品一区二区三区,91久久精品美女高潮喷水APP,国产精品久久久久久蜜桃传媒,色婷婷国产精品综合在线观看,yy6080亚洲人久久精品第一区